Oxygen Transmission Rate Tester – Coulometric Sensor Method
A coulometric sensor dedicated to oxygen, with a film lower limit of 0.01 cm³/m²·24h·0.1MPa and a container lower limit of 0.00005 g/pkg·24h — the workhorse for oxygen barrier evaluation in pharmaceuticals, food and high-barrier packaging.
Purpose | What it does for you
Purpose-built for oxygen transmission rate (OTR) of plastic films, sheets, laminates and containers. Oxygen drives oxidative rancidity in food, degradation of drugs and spoilage of cosmetics, making OTR one of the most frequently requested metrics in packaging selection and shelf-life design. The coulometric sensor responds only to oxygen, offering excellent selectivity and sensitivity across a wide range from ordinary films to high-barrier metallised structures.
Key Features
- Coulometric sensor responding only to oxygen: excellent selectivity and sensitivity
- Film lower limit 0.01 and container 0.00005, covering ordinary films to high-barrier metallised films
- Whole-container (bottle, pouch) testing for results closer to real shelf performance
- Automatic temperature and humidity control (15–45 °C, 35–90% RH) with strong environmental adaptability
- Pneumatic clamping with anti-leak sealing for consistent mounting
- Graphical full-process monitoring, multi-format reports; optional GMP Computerized System module
Operating Principle
Carrier gas (high-purity nitrogen) flows at a set rate on one side of the specimen while oxygen (or air) flows on the other. The oxygen partial-pressure difference drives oxygen through the specimen, and the permeated oxygen is carried to the coulometric sensor. The sensor generates a current proportional to oxygen concentration, from which OTR is calculated.
Technical Specifications
| Measurement Range | Film 0.01–10,000 / 0.01–14,000 cm³/m²·24h·0.1MPa; container 0.00005–40 / 0.00005–50 g/pkg·24h |
|---|---|
| Measurement Resolution | Film 0.01; container 0.00005 |
| Temperature Range | 15–45 ℃ |
| Temperature Error | ±0.3 ℃ |
| Humidity Range | 35%–90% RH |
| Humidity Error | ±2% RH |
| Test Area | 50 cm² / 38.48 cm² |
| Carrier Gas | 99.999% N₂ |
| Flow Rate | 0–50 or 0–300 cm³/min |
| Power Supply | AC 220/110 V ±10%,50/60 Hz |
Note: Due to continuous product iteration and varying application conditions, the technical parameters on this page are typical reference values and are not to be used as acceptance criteria. For tender and customized projects, the product model, configuration and specifications are subject to the mutually confirmed technical agreement and the actual delivered product. For parameter matching tailored to your specific project, please contact us.
Models & Configuration
| Model | OTR-E-11-G | OTR-E-31-H | OTR-E-41-G |
|---|---|---|---|
| Specimen Count | 1 | 3 | 4 |
| Test Area | 50 cm² | 38.48 cm² | 50 cm² |
| Dimensions | 415×720×400 mm | 520×778×475 mm | 415×720×400 mm |
| Net Weight | 69 kg | 83 kg | 90 kg |
Standard Configuration
Main unit, test computer, professional software, oxygen trap, specimen sampler, two pressure reducing valves, sealing grease. User supplies high-purity nitrogen, oxygen (or air) and distilled water.
Application Scenarios
- OTR selection for oxidation-prone foods: edible oils, nuts, meat products
- Oxygen barrier verification for pharmaceutical blisters, infusion bags and sterile packaging
- OTR quality control of PET bottles and preforms for beer, juice and dairy
- Evaluation of cosmetic tubes, airless bottles and high-barrier films
Compliance Standards
Industries Served
- Food & Condiments
- Pharmaceutical & Biopharmaceutical
- Packaging & Printing
- Cosmetics & Personal Care
- Medical Devices
- Material R&D, Universities & Institutes
- Third-Party & Government Testing Institutes
- Public Health CDC & Customs Technical Centers
Frequently Asked Questions
Why choose coulometric over differential pressure for oxygen?
The coulometric sensor responds only to oxygen, giving better selectivity, higher sensitivity and a lower detection limit (down to 0.01 for films), free from interference by other gases. The differential-pressure method suits work needing multi-gas switching or solubility/diffusion coefficients. If OTR is your core metric, coulometric is usually the better fit.
Why does the coulometric method require 99.999% high-purity nitrogen as carrier gas?
The coulometric sensor responds only to oxygen: permeated O₂ is reduced at the sensor, producing a current proportional to the amount present. The carrier gas transports that oxygen into the sensor, so it must itself be oxygen-free. Insufficient purity raises the baseline reading — the error is most pronounced on high-barrier materials, where transmission is already low, and can render results non-discriminating. It is the most easily overlooked precondition of this method.
Should I use film mode or container mode?
It depends on the question you need answered. Film mode characterises the material itself (test area 50 cm² or 38.48 cm², resolution 0.01) — use it for material selection and incoming inspection. Container mode measures the finished bottle, pouch or tray directly (resolution 0.00005, range 0.00005–40), because forming, heat sealing and creasing all alter barrier performance: the same material can differ by more than an order of magnitude between flat film and a formed container. For shelf-life decisions and regulatory claims, test the finished container.
How do I choose between the gravimetric cup, electrolytic and infrared WVTR methods?
Choose by range and purpose. The gravimetric cup method is closest to the pharmacopoeia and ASTM E96 classic: a wide range, finished containers can be measured directly, but each run is long — best for compliance comparison and referee testing. The electrolytic method is an absolute coulometric method suited to low-transmission films and containers. The infrared (TDLAS) method responds fast and suits trace water vapour in high-barrier materials and high-throughput work. Pick the cup method when compliance leads, electrolytic or infrared when line efficiency leads.
What is the difference between differential-pressure and equal-pressure (coulometric) gas transmission testing?
The differential-pressure method creates a pressure difference across the specimen and tracks the pressure rise on the low-pressure side; one instrument measures oxygen, carbon dioxide, nitrogen and other non-toxic gases, making it the general-purpose choice. The equal-pressure method keeps both sides at the same pressure and uses a coulometric sensor for oxygen only, giving higher sensitivity for the extremely low OTR of high-barrier materials. Two rules: choose differential pressure when you need several gases, coulometric when you measure oxygen only and need the lowest detection limit.
Why does high-barrier gas transmission testing take so long?
Because the transmitted amount is extremely small, you must wait until permeation reaches steady state and the accumulated signal exceeds the instrument resolution; temperature and humidity equilibration and the system background (residual oxygen or water vapour) also take time. Practical ways to shorten it: raise the test temperature and note it in the report, reduce background and leaks, use a more sensitive sensor, and add parallel test chambers. No speed-up should compromise the steady-state criterion.
How much do temperature and humidity conditions affect barrier results?
The effect is significant: conditions must match the method standard and be stated in the report. Higher temperature raises transmission; for hydrophilic materials, a change in relative humidity markedly changes both water vapour and oxygen transmission. This instrument controls 15–45 °C to ±0.3 °C and covers 35%–90% RH (some models also offer 0% RH). Before comparing data between laboratories, check that both used the same temperature and humidity.
Does LabStone support OEM/ODM and customised instruments?
Yes. Standard models ship as-is, while chamber count, specimen size, fixtures, temperature range and software modules (including the GMP Computerized System module) can be tailored to your SOP and URS. IQ/OQ/PQ validation documentation packages are available.
What is the typical lead time, and how is shipping handled?
Standard models usually ship in 4–8 weeks; customised builds depend on the agreed scope. Instruments are packed in export wooden cases and can move by sea, air or rail. We supply proforma invoice, packing list and certificate of origin (CO / Form E), and work under EXW, FOB, CIF or DAP terms.
How are installation, training and calibration handled after delivery?
We provide remote installation guidance, bilingual (Chinese/English) manuals and video training; on-site commissioning by our engineers is available. Users can self-calibrate with standard weights, reference films or calibrated leak standards, and third-party calibration certificates can be supplied.
What is the warranty, and how are spare parts supplied?
The instrument carries a 12-month warranty from acceptance plus lifetime maintenance support. Consumables (molecular sieve, desiccant, sealing grease, printer paper) are kept in long-term stock, and key components are international brands available worldwide. We respond to technical enquiries within 24 hours.
Do the instruments comply with ASTM, ISO and pharmacopoeia standards?
Yes. Every instrument lists its applicable standards on the specification page (ASTM, ISO, GB, YBB, Chinese Pharmacopoeia, USP, EP, JIS, DIN, TAPPI and more). The software outputs raw records and reports suitable for audit trails, with an optional GMP / FDA 21 CFR Part 11 compliance module.
Which languages does the software support, and can it integrate with a LIMS?
The software ships with Chinese and English interfaces; other languages can be added on request. Data export is available over RS232, USB, Ethernet or Wi-Fi, and reports can be exported to Excel, PDF or structured files for LIMS integration.