Water Vapor Transmission Rate Tester – Electrolytic Method
An absolute coulometric electrolytic sensor electrolyses all permeated water vapour and measures absolute water content — ultra-high precision with stable relative error, the classic choice for high-barrier materials.
Purpose | What it does for you
Determines water vapour transmission of films, sheets, containers and building materials made of plastic, textile, leather or metal. As an absolute coulometric method, the sensor electrolyses all permeated vapour, giving extremely high precision with stable relative error — especially suitable for long-duration, low-transmission tests on foil laminates and metallised high-barrier films.
Key Features
- Electrolytic detection sensor, absolute coulometric method
- Ultra-high precision with stable relative error
- Fully automatic fog-free humidity control at 35–90% RH and 100% RH
- Semiconductor bidirectional temperature control, high precision and reliability
- Pneumatic H-type clamping with anti-leak specimen sealing
- Strong environmental adaptability: indoor 10–30 °C at any humidity, low running cost
- Power-on self-check plus one-key fully automatic start; graphical monitoring and multi-format reports
Operating Principle
Nitrogen at a set humidity flows on one side of the specimen while dry nitrogen (carrier gas) flows at a fixed rate on the other. The humidity difference drives water vapour from the high-humidity to the low-humidity side, and the permeated vapour is carried to the electrolytic sensor. The sensor electrolyses all water vapour in the carrier gas, measures the absolute water content, and WVTR is calculated from it.
Technical Specifications
| Measurement Range | Film 0.001–20 / 0.001–25 g/m²·24h; container 0.00005–0.1 g/pkg·24h |
|---|---|
| Measurement Resolution | 0.001 g/m²·24h (0.0001 g/m²·24h optional) |
| Temperature Range | 15–45 ℃ |
| Temperature Error | ±0.3 ℃ |
| Humidity Range | 0% RH,35%–90% RH / 0% RH, 35%–90% RH |
| Humidity Error | ±2% RH |
| Specimen Thickness | <3 mm |
| Operating Environment | 10–30 ℃ |
| Carrier Gas | 99.999% N₂ |
| Flow Rate | 0–100 or 0–300 cm³/min |
| Gas Supply Pressure | ≥0.2 MPa |
| Interface Size | 1/8 in metal tube |
| Power Supply | AC 220/110 V ±10%,50/60 Hz |
Note: Due to continuous product iteration and varying application conditions, the technical parameters on this page are typical reference values and are not to be used as acceptance criteria. For tender and customized projects, the product model, configuration and specifications are subject to the mutually confirmed technical agreement and the actual delivered product. For parameter matching tailored to your specific project, please contact us.
Models & Configuration
| Model | W-E-11-G | W-E-31-H | W-E-41-G |
|---|---|---|---|
| Specimen Count | 1 | 3 | 4 |
| Test Area | 50 cm² | 38.48 cm² | 50 cm² |
| Dimensions | 415×720×400 mm | 520×778×475 mm | 415×720×400 mm |
| Net Weight | 53 kg | 73 kg | 85 kg |
Standard Configuration
Mainframe, test computer, professional software, water trap, sampler, nitrogen cylinder regulator, sealing grease. Optional: container test kit, container temperature control kit, specimen masks (7 cm² / 1 cm²). User supplies high-purity nitrogen and distilled water.
Application Scenarios
- Ultra-low transmission of pharmaceutical foils and high-barrier laminated pouches
- Barrier validation of long shelf-life food packaging
- Comparative WVTR testing of building materials and geomembranes
Compliance Standards
Industries Served
- Pharmaceutical & Biopharmaceutical
- Food & Condiments
- Packaging & Printing
- Material R&D, Universities & Institutes
- Building Materials & Construction
- Third-Party & Government Testing Institutes
Frequently Asked Questions
Which suits me better, electrolytic or infrared?
Both are sensor methods with high precision. The electrolytic method is absolute coulometric with a lower detection limit and better stability for long, low-transmission runs; the infrared method is faster with no sensor equilibration wait, suiting high sample volumes. Send us representative samples and we will run a comparison and advise.
Why is the electrolytic method called an absolute method, and what does that mean for data credibility?
Because the sensor electrolyses all the vapour that permeates the specimen, and the charge produced stands in a strict stoichiometric relationship to the amount of water — it measures an absolute quantity rather than a reading against a calibration curve. The result is a stable relative error: film range 0.001–20 g/m²·24h (a 0.001–25 variant also exists), resolution 0.001 g/m²·24h, upgradeable to 0.0001. For low-transmission materials that must be compared over the long term, or whose numbers go into a regulatory file, this independence from a calibration curve is worth a great deal.
Both the electrolytic and infrared methods handle high-barrier materials — how do I choose?
They share a lot: both are sensor methods, both use 99.999% high-purity nitrogen as carrier gas, both operate at 15–45 °C and cover 0% RH as well as 35%–90% RH. The difference is in range structure and where each is stronger. The electrolytic method covers 0.001–20 g/m²·24h for films with 0.001 resolution (upgradeable to 0.0001) — a finer scale in the very-low-transmission region. The infrared method covers 0.005–100 g/m²·24h for films and, in container mode, 0.00005–0.5 g/pkg·24h at 0.00001 resolution — a wider span, and notably strong on finished containers. Rule of thumb: for fine comparisons confined to very low transmission, take the electrolytic method or the high-resolution option; to cover both films and finished containers, or to span high to medium barrier, take the infrared method. If you have both, cross-checking the same specimen will strengthen comparability further.
How do I choose between the gravimetric cup, electrolytic and infrared WVTR methods?
Choose by range and purpose. The gravimetric cup method is closest to the pharmacopoeia and ASTM E96 classic: a wide range, finished containers can be measured directly, but each run is long — best for compliance comparison and referee testing. The electrolytic method is an absolute coulometric method suited to low-transmission films and containers. The infrared (TDLAS) method responds fast and suits trace water vapour in high-barrier materials and high-throughput work. Pick the cup method when compliance leads, electrolytic or infrared when line efficiency leads.
What is the difference between differential-pressure and equal-pressure (coulometric) gas transmission testing?
The differential-pressure method creates a pressure difference across the specimen and tracks the pressure rise on the low-pressure side; one instrument measures oxygen, carbon dioxide, nitrogen and other non-toxic gases, making it the general-purpose choice. The equal-pressure method keeps both sides at the same pressure and uses a coulometric sensor for oxygen only, giving higher sensitivity for the extremely low OTR of high-barrier materials. Two rules: choose differential pressure when you need several gases, coulometric when you measure oxygen only and need the lowest detection limit.
Why does high-barrier gas transmission testing take so long?
Because the transmitted amount is extremely small, you must wait until permeation reaches steady state and the accumulated signal exceeds the instrument resolution; temperature and humidity equilibration and the system background (residual oxygen or water vapour) also take time. Practical ways to shorten it: raise the test temperature and note it in the report, reduce background and leaks, use a more sensitive sensor, and add parallel test chambers. No speed-up should compromise the steady-state criterion.
How much do temperature and humidity conditions affect barrier results?
The effect is significant: conditions must match the method standard and be stated in the report. Higher temperature raises transmission; for hydrophilic materials, a change in relative humidity markedly changes both water vapour and oxygen transmission. This instrument controls 15–45 °C to ±0.3 °C and covers 35%–90% RH (some models also offer 0% RH). Before comparing data between laboratories, check that both used the same temperature and humidity.
Does LabStone support OEM/ODM and customised instruments?
Yes. Standard models ship as-is, while chamber count, specimen size, fixtures, temperature range and software modules (including the GMP Computerized System module) can be tailored to your SOP and URS. IQ/OQ/PQ validation documentation packages are available.
What is the typical lead time, and how is shipping handled?
Standard models usually ship in 4–8 weeks; customised builds depend on the agreed scope. Instruments are packed in export wooden cases and can move by sea, air or rail. We supply proforma invoice, packing list and certificate of origin (CO / Form E), and work under EXW, FOB, CIF or DAP terms.
How are installation, training and calibration handled after delivery?
We provide remote installation guidance, bilingual (Chinese/English) manuals and video training; on-site commissioning by our engineers is available. Users can self-calibrate with standard weights, reference films or calibrated leak standards, and third-party calibration certificates can be supplied.
What is the warranty, and how are spare parts supplied?
The instrument carries a 12-month warranty from acceptance plus lifetime maintenance support. Consumables (molecular sieve, desiccant, sealing grease, printer paper) are kept in long-term stock, and key components are international brands available worldwide. We respond to technical enquiries within 24 hours.
Do the instruments comply with ASTM, ISO and pharmacopoeia standards?
Yes. Every instrument lists its applicable standards on the specification page (ASTM, ISO, GB, YBB, Chinese Pharmacopoeia, USP, EP, JIS, DIN, TAPPI and more). The software outputs raw records and reports suitable for audit trails, with an optional GMP / FDA 21 CFR Part 11 compliance module.
Which languages does the software support, and can it integrate with a LIMS?
The software ships with Chinese and English interfaces; other languages can be added on request. Data export is available over RS232, USB, Ethernet or Wi-Fi, and reports can be exported to Excel, PDF or structured files for LIMS integration.